#Profibus_DP GSD_Revision = 5 Vendor_Name = "SIC" Model_Name = "M8000" Revision = "1.1" Ident_Number = 0x0C46 Protocol_Ident = 0 Station_Type = 0 FMS_supp = 0 Hardware_Release = "2.70" Software_Release = "2.32" 9.6_supp=1 19.2_supp=1 45.45_supp=1 93.75_supp=1 187.5_supp=1 500_supp=1 1.5M_supp=1 MaxTsdr_9.6=60 MaxTsdr_19.2=60 MaxTsdr_45.45=250 MaxTsdr_93.75=60 MaxTsdr_187.5=60 MaxTsdr_500=100 MaxTsdr_1.5M=150 Redundancy = 0 Bitmap_Device="SIC0C46" Repeater_Ctrl_Sig = 0 24V_Pins = 0 Implementation_Type = "SPC4" Freeze_Mode_supp = 0 Sync_Mode_supp = 0 Fail_Safe = 0 Auto_Baud_supp = 1 Min_Slave_Intervall = 20 Modular_Station = 0 Max_Module = 1 Max_Input_Len = 7 ; maximum Input Length Max_Output_Len = 4 ; maximum Output Length Max_Data_Len = 11 ; maximum In-Output Length Slave_Family = 1@TdF@SIC Max_Diag_Data_Len = 6 Set_Slave_Add_supp = 1 Max_User_Prm_Data_Len = 3 User_Prm_Data_Len = 3 Ext_User_Prm_Data_Const(0)=0x80,0x00,0x00 PrmText=1 Text(0)="Disabled" Text(1)="Enabled" EndPrmText ;----------- Description of extended DP features: --------------------- ; ;DPV1 CAPABILITY DPV1_Slave = 1 DPV1_Data_Types = 0 ; ; C1_Read_Write C1_Read_Write_supp = 1 C1_Max_Data_Len = 48 C1_Response_Timeout = 4000 ;C1_Max_Count_Channels = 2 ;C1_Read_Write_required = 0 ; ; C2_Read_Write ; Max_Iniitiate_PDU_Length =52 C2_Read_Write_supp = 1 C2_Max_Data_Len = 48 C2_Response_Timeout = 4000 C2_Max_Count_Channels = 1 ;C2_Read_Write_required = 1 ; ; ; I&M function supported Ident_Maintenance_supp = 1 ; ;--- Description of physical interface for async. and sync. transmission: --- ;Physical_Interface = 1 ; RS-485 Standard Copper ;Transmission_Delay_45.45 = 0 ;Reaction_Delay_45.45 = 0 ;Transmission_Delay_93.75 = 0 ;Reaction_Delay_93.75 = 0 ;End_Physical_Interface ; ;Physical_Interface = 0 ; 0: RS 485 Standard Copper 1: IEC61158-2 ;Transmission_Delay_31.25 = 0 ;Reaction_Delay_31.25 = 0 ;End_Physical_Interface ;----------- Description of device related diagnosis: --------------------- ; ;Unit_Diag_Bit(16) = "Error appears" ;Unit_Diag_Bit(17) = "Error disappears" ;Unit_Diag_Bit(24) = "Hardware failure electronics" ;Unit_Diag_Bit(25) = "Hardware failure mechanics" ;Unit_Diag_Bit(26) = "Motor temperature too high" ;Unit_Diag_Bit(27) = "Electronic temperature too high" ;Unit_Diag_Bit(28) = "Memory error" ;Unit_Diag_Bit(29) = "Measurement failure" ;Unit_Diag_Bit(30) = "Device not initialized" ;Unit_Diag_Bit(31) = "Device initialization failed" ;Unit_Diag_Bit(32) = "Zero point error" ;Unit_Diag_Bit(33) = "Power supply failed" ;Unit_Diag_Bit(34) = "Configuration invalid" ;Unit_Diag_Bit(35) = "Restart" ;Unit_Diag_Bit(36) = "Coldstart" ;Unit_Diag_Bit(37) = "Maintenance required" ;Unit_Diag_Bit(38) = "Characteristics invalid" ;Unit_Diag_Bit(39) = "Ident_Number violation" ;Unit_Diag_Bit(40) = "Maintenance Alarm" ;Unit_Diag_Bit(41) = "Maintenance Demanded" ;Unit_Diag_Bit(42) = "Function Check" ;Unit_Diag_Bit(55) = "Extension Available" ;------------------------------------------------------------------------------ Module ="RunStatus+ReadBack+SetPD+SetP" 0x16,0x23 1 EndModule