#Profibus_DP GSD_Revision = 5 Vendor_Name = "ChongQing" Model_Name = "PDS 8" Revision = "1.0" Ident_Number =0x0CC2;9701 Protocol_Ident = 0 Station_Type = 0 FMS_supp = 0 Hardware_Release = "V1.0" Software_Release = "V1.0" 31.25_supp = 1 45.45_supp = 1 93.75_supp = 1 MaxTsdr_31.25 = 100 MaxTsdr_45.45 = 250 MaxTsdr_93.75 = 1000 Redundancy = 0 Repeater_Ctrl_Sig = 0 24V_Pins = 0 Freeze_Mode_supp = 0 Sync_Mode_supp = 0 Set_Slave_Add_supp = 1 Min_Slave_Intervall = 250 Modular_Station = 1 Max_Module = 2 Max_Input_Len = 10 ; maximum Input Length Max_Output_Len = 0 ; maximum Output Length Max_Data_Len = 10 ; maximum In-Output Length Slave_Family = 12 Max_Diag_Data_Len = 20 ;20 Max_User_Prm_Data_Len = 3 PrmText=1 Text(0)="Disabled" Text(1)="Enabled" EndPrmText ExtUserPrmData=1 "Condensed Status" Bit(0) 1 0-1 ;PRM_COND Prm_Text_Ref=1 ;reference to PrmText EndExtUserPrmData Ext_User_Prm_Data_Const(0) = 0x00, 0x00, 0x00 Prm_Block_Structure_supp=1 ;enables the block structure of extended parameterization ;----------- Description of extended DP features: --------------------- ; DPV1_Slave = 1 C2_Read_Write_supp = 1 C2_Max_Data_Len = 128 C2_Read_Write_required = 1 C2_Max_Count_Channels = 2 Max_Initiate_PDU_Length = 52 C2_Response_Timeout = 4000 DPV1_Data_Types = 1 Ident_Maintenance_supp = 1 ;--- Description of physical interface for async. and sync. transmission: --- Physical_Interface = 0 ; RS-485 Standard Copper Transmission_Delay_45.45 = 0 Reaction_Delay_45.45 = 0 Transmission_Delay_93.75 = 0 Reaction_Delay_93.75 = 0 End_Physical_Interface ; Physical_Interface = 1 ; IEC61158-2 Transmission_Delay_31.25 = 0 Reaction_Delay_31.25 = 0 End_Physical_Interface ;----------- Description of device related diagnosis: --------------------- ; ;Unit_Diag_Bit(16) = "Error appears" ;Unit_Diag_Bit(17) = "Error disappears" ;Unit_Diag_Bit(24) = "Hardware failure electronics" ;Unit_Diag_Bit(25) = "Hardware failure mechanics" ;Unit_Diag_Bit(26) = "Motor temperature too high" ;Unit_Diag_Bit(27) = "Electronic temperature too high" ;Unit_Diag_Bit(28) = "Memory error" ;Unit_Diag_Bit(29) = "Measurement failure" ;Unit_Diag_Bit(30) = "Device not initialized" ;Unit_Diag_Bit(31) = "Device initialization failed" ;Unit_Diag_Bit(32) = "Zero point error" ;Unit_Diag_Bit(33) = "Power supply failed" ;Unit_Diag_Bit(34) = "Configuration invalid" ;Unit_Diag_Bit(35) = "Restart" Unit_Diag_Bit(36) = "Coldstart" ;Unit_Diag_Bit(37) = "Maintenance required" ;Unit_Diag_Bit(38) = "Characteristics invalid" ;Unit_Diag_Bit(39) = "Ident_Number violation" ;Unit_Diag_Bit(55) = "Extension Available" ;Unit_Diag_Bit(56) = "Diagnostics Cutoff" ;Unit_Diag_Bit(57) = "Empty Sensor" ;Unit_Diag_Bit(58) = "Coil Off" ;Unit_Diag_Bit(59) = "Cable Short" ;Unit_Diag_Bit(60) = "Volume Flow Low Limit" ;Unit_Diag_Bit(61) = "Volume Flow High Limit" ;------------------------------------------------------------------------- ;Empty module Module = "EMPTY_MODULE" 0x00 1 EndModule ; ;Modules for pressure device Module = "AI" 0x94 2 EndModule Module = "AI_EXT" 0x42,0x84,0x08,0x05 3 EndModule Module = "AI1" 0x94 4 EndModule Module = "A1I_EXT" 0x42,0x84,0x08,0x05 5 EndModule ;----------- Description of the module assignment: --------------------- ; SlotDefinition Slot(1) = "AIalog Input 1" 2 1,2,3 Slot(2) = "Analog Input 2" 4 1,4,5 EndSlotDefinition